Study analyzes effectiveness of reflective ceilings

Study analyzes effectiveness of reflective ceilings

Engineers at Brinjac quantify the illuminance and energy consumption levels achieved by increasing the ceiling’s light reflectance.


By C.C. Sullivan and Barbara Horwitz-Bennett | September 16, 2013
To quantify the illuminance and energy consumption levels achieved by increasing the ceiling’s light reflectance (LR), ceiling system manufacturer Armstrong World Industries commissioned Brinjac Engineering to conduct two controlled studies. (Illuminance is a measure of the intensity of light on a unit area of a surface.)
 
In the first study, four different room configurations were outfitted with a direct recessed 2X2-foot parabolic troffer and an indirect pendant. One set of rooms was given a 75% reflective ceiling; the others, a 90% reflective ceiling. After measuring work plane illuminance in both sets of rooms, Brinjac found the 0.90 LR ceiling to increase direct lighting levels by just 2–5%; however, indirect lighting levels jumped by almost 22% and offered greater lighting uniformity.
 
Although work plane illuminance from direct lighting only increased modestly when changing the light reflectance from 0.75 to 0.90, the effect of indirect lighting on work plane illuminance was significant. In addition, the higher LR value enabled a reduction in indirect luminaire fixtures and a decrease in lighting power density.
 
Based on these results, specifiers can use fewer fixtures or lower wattage levels to achieve required lighting levels, which can reduce energy costs, as analyzed in the second study where the 90% reflective ceiling tile was installed in the same spaces with an optimized lighting design and compared to the 75% and 90% ceiling with the original lighting scheme.
 
After comparing the three ceiling designs, the Brinjac researchers found that:
• Spacing between indirect luminaire sections with the 0.90 ceiling could be increased, thereby reducing the total number of luminaires required to achieve light levels afforded by the 0.75 ceiling.
• The 0.90 reflective ceiling with indirect fixtures yielded a 23% lower lighting power density than the 0.75 ceiling, and 21% lower than the parabolic troffer layout.
• This lighting power density reduction was calculated to achieve 9% HVAC energy costs savings, as compared to the 0.75 ceiling, and 7% in relation to the troffer layout.
 
For more information on this study, see: http://www.armstrong.com/common/c2002/content/files/38652.pdf. 

Related Stories

| Jul 21, 2011

Bringing BIM to the field

A new tablet device for construction professionals puts 3D data at the fingertips of project managers and construction supervisors.

| Nov 2, 2010

11 Tips for Breathing New Life into Old Office Spaces

A slowdown in new construction has firms focusing on office reconstruction and interior renovations. Three experts from Hixson Architecture Engineering Interiors offer 11 tips for office renovation success. Tip #1: Check the landscaping.

| Oct 13, 2010

Test run on the HP Z200 SFF Good Value in a Small Package

Contributing Editor Jeff Yoders tests a new small-form factor, workstation-class desktop in Hewlett-Packard’s line that combines performance of its minitower machine with a smaller chassis and a lower price.

| Oct 13, 2010

Prefab Trailblazer

The $137 million, 12-story, 500,000-sf Miami Valley Hospital cardiac center, Dayton, Ohio, is the first major hospital project in the U.S. to have made extensive use of prefabricated components in its design and construction.

| Oct 13, 2010

Community center under way in NYC seeks LEED Platinum

A curving, 550-foot-long glass arcade dubbed the “Wall of Light” is the standout architectural and sustainable feature of the Battery Park City Community Center, a 60,000-sf complex located in a two-tower residential Lower Manhattan complex. Hanrahan Meyers Architects designed the glass arcade to act as a passive energy system, bringing natural light into all interior spaces.

boombox1 - default
boombox2 -
native1 -

More In Category

AEC Tech

Lack of organizational readiness is biggest hurdle to artificial intelligence adoption

Managers of companies in the industrial sector, including construction, have bought the hype of artificial intelligence (AI) as a transformative technology, but their organizations are not ready to realize its promise, according to research from IFS, a global cloud enterprise software company. An IFS survey of 1,700 senior decision-makers found that 84% of executives anticipate massive organizational benefits from AI. 




halfpage1 -

Most Popular Content

  1. 2021 Giants 400 Report
  2. Top 150 Architecture Firms for 2019
  3. 13 projects that represent the future of affordable housing
  4. Sagrada Familia completion date pushed back due to coronavirus
  5. Top 160 Architecture Firms 2021