A new rule from the Steel Joist Institute clarifies when local reinforcement of joists is required for chord loads away from panel points. SJI members offer guidance about how and when to specify loads.


By By Susan Bady, Contributing Editor | January 3, 2012
New SJI Rule on Steel Joists
According to a new rule issued by the Steel Joist Institute, the proper way to hang loads from joist chords is concentrically (n
This article first appeared in the January 2012 issue of BD+C.

For years, the steel joist industry standard has been that loads either need to be applied at panel points, or a member brace (strut) must be added in the field. In response to inquiries from structural engineers and other members of the Building Team, the Steel Joist Institute recently issued a new rule for loads not exceeding 100 pounds within any given panel.Ā 

The full text of the SJI rule reads as follows: ā€œFor nominal concentrated loads between panel points, which have been accounted for in the specified uniform design loads, a strut to transfer the load to a panel point on the opposite chord shall not be required, provided the sum of the concentrated loads within a chord panel does not exceed 100 pounds and the attachments are concentric to the chord.ā€

Bruce Brothersen, engineering manager for Vulcraft-Utah, Brigham, Utah, says, ā€œThe rule is an attempt to better define what is acceptable and put some quantitative numbers to it.ā€

Tim Holtermann, corporate engineering manager for Canam Steel in Washington, Mo., says that even with the new rule, manufacturers remain concerned that ā€œpeople may be hanging things in excess of 100 pounds away from panel points and not field-adding struts, as theyā€™re required to do.ā€

Holtermann says one option for structural engineers is to ask the manufacturer to provide a specially designed joist that can take point loads over 100 pounds without the added members. ā€œItā€™s not uncommon to have a design requirement for, say, 250 pounds or 400 pounds,ā€ he says. ā€œWe can readily do that as long as the magnitude of the loads and this design requirement are specified on the contract drawings.ā€

DONā€™T WAIT FOR THE FINAL PUNCH LIST
Often the problem with the joist loads isnā€™t discovered until the project is completed and the final walkthrough is taking place, says Joe Pote, director of research and development for New Millennium Building Systems, Hope, Ark.

ā€œThe inspector notices ductwork or sprinkler lines or mechanicals hanging from the joists between panel points that arenā€™t called out on the contract drawings,ā€ says Pote. ā€œThen he comes back to us and asks if itā€™s okay.ā€ Many times the loads are small (20-50 pounds), so additional reinforcementĀ isnā€™t necessary. ā€œBut we never had a good rule that stated the maximum load,ā€ he says. ā€œI think it helps clear up some of the discrepancy between SJI requirements and actual field practice.ā€

The manner in which the loads are hung is a key element of the 100-pound rule, says Holtermann. ā€œThe rule presumes that the load will be placed concentrically,ā€ he says.

As SJI managing director Ken Charles notes, some trade installers make the mistake of attaching beam clamps to only one bottom chord angle of the joist instead of both. On top of that, he says, ā€œthe load isnā€™t placed concentrically even to that one chord angle, so youā€™re inducing some torsion and bending of the horizontal leg of the angle.ā€

His advice: ā€œBy far the better way to do it is to make sure the attachment is always concentric and always attached to both chord angles.ā€ (See diagram.)

Steel Joist Doā€™s and Donā€™ts

  • Recognize how and when to specify total uniform load or factored load and/or net uplift load, and when loads need to be broken out by load category and combinations.
  • Know the limits of a concentrated load applied between panel points before an additional web is needed on the joist. The Steel Joist Instituteā€™s new ā€œ100-pound ruleā€ clarifies these limits.
  • Install bridging early and follow the proper procedures to avoid safety problems, such as a partial building collapse.
  • Designate a field representative to inspect the joists during construction and ensure that components are being installed correctly.Ideally, a representative of the team should walk the job site before completion and look for situations where loads arenā€™t handled correctly.

ā€œA lot of times thereā€™s a disconnect between the design intent and the construction site personnel,ā€ says Charles. ā€œSome sites have representatives in the field to do inspections, but often thatā€™s not the case. Those are the projects that are most likely to have problems down the road when the final punch list is done.ā€

GET YOUR SPECS STRAIGHT
Joists are designed to handle different types of loads, such as dead load, live load, and wind, snow, and seismic loads. A given joist might experience more than one type of load, so the joist manufacturer needs to know which loads apply and properly combine them according to parameters set by the International Building Code. Most jurisdictions use the 2006 version of the IBC or the 2009 version, which is similar with regard to steel joists.

Brothersen notes that the building code loading combinations are based on the probability of which loads will act simultaneously. ā€œFor instance, the probability of a seismic event occurring when the maximum snow load is on the joist is relatively small, so the building code reduces the loads in those cases,ā€ he says. ā€œThis is more realistic and doesnā€™t require manufacturers to design for the maximum load in every category at the same time.ā€

Pote says manufacturers prefer, when itā€™s feasible, that loads be provided to them as either a total uniform load or a factored load. In other words, if all components of the joist can be designed for a single downward-acting load case and a single upward-acting load case, the easiest thing for engineers to do is provide the total uniform load and/or net uplift load (dead load minus wind load).

ā€œItā€™s just easier to communicate,ā€ says Charles. ā€œHowever, if we have to consider multiple load combinations, we need the breakdownā€”dead load, live load, snow load, and so forth.ā€

Holtermann adds that if the structure might be affected by downward-acting winds, the total uniform load should assume the worst-case scenario.

DONā€™T FORGET THE BRIDGING
Once the joists arrive on site, itā€™s important that bridging be installed early and correctly, says Brothersen. ā€œIf the joists are put up but the bridging isnā€™t installed, it can become a safety issue.ā€ For example, lack of bridging can result in a partial building collapse when the crew begins stacking bundles of deck material on the joists.

Charles agrees. ā€œThe best-laid plans of the engineer and manufacturer can go out the window when the product arrives at the job site and the erector doesnā€™t follow proper safety regulations and the manufacturerā€™s advice.ā€ BD+C
--
Editorā€™s note: To order SJIā€™s ā€œ43rd Edition Catalog of Standard Specifications and Load and Weight Tables for Steel Joists and Joist Girders,ā€ go to: http://steeljoist.org/free-download-form.

Related Stories

Healthcare Facilities | Mar 18, 2024

A modular construction solution to the mental healthcare crisis

Maria Ionescu, Senior Medical Planner, Stantec, shares a tested solution for the overburdened emergency department: Modular hub-and-spoke design.

Codes and Standards | Mar 18, 2024

New urban stormwater policies treat rainwater as a resource

U.S. cities are revamping how they handle stormwater to reduce flooding and capture rainfall and recharge aquifers. New policies reflect a change in mindset from treating stormwater as a nuisance to be quickly diverted away to capturing it as a resource.

Plumbing | Mar 18, 2024

EPA to revise criteria for WaterSense faucets and faucet accessories

The U.S. Environmental Protection Agency (EPA) plans to revise its criteria for faucets and faucet accessories to earn the WaterSense label. The specification launched in 2007; since then, most faucets now sold in the U.S. meet or exceed the current WaterSense maximum flow rate of 1.5 gallons per minute (gpm).Ā 

MFPRO+ New Projects | Mar 18, 2024

Luxury apartments in New York restore and renovate a century-old residential building

COOKFOX ArchitectsĀ has completed a luxury apartment building at 378 West End Avenue in New York City. The project restored and renovated the original residence built in 1915, while extending a new structure east on West 78th Street.Ā 

Multifamily Housing | Mar 18, 2024

YWCA building in Bostonā€™s Back Bay converted into 210 affordable rental apartments

Renovation of YWCA at 140 Clarendon Street will serve 111 previously unhoused families and individuals.

Healthcare Facilities | Mar 17, 2024

5 criteria to optimize medical office design

Healthcare designers need to consider privacy, separate areas for practitioners, natural light, outdoor spaces, and thoughtful selection of materials for medical office buildings.

Construction Costs | Mar 15, 2024

Retail center construction costs for 2024

Data from Gordian shows the most recent costs per square foot for restaurants, social clubs, one-story department stores, retail stores and movie theaters in select cities.

Architects | Mar 15, 2024

4 ways to streamline your architectural practice

Vessel Architecture's Lindsay Straatmann highlights four habits that have helped her discover the key to mastering efficiency as an architect.

Healthcare Facilities | Mar 15, 2024

First comprehensive cancer hospital in Dubai to host specialized multidisciplinary care

Stantec was selected to lead the design team for the Hamdan Bin Rashid Cancer Hospital, Dubaiā€™s first integrated, comprehensive cancer hospital. Named in honor of the late Sheikh Hamdan Bin Rashid Al Maktoum, the hospital is scheduled to open to patients in 2026.

Codes and Standards | Mar 15, 2024

Technical brief addresses the impact of construction-generated moisture on commercial roofing systems

A new technical brief from SPRI, the trade association representing the manufacturers of single-ply roofing systems and related component materials, addresses construction-generated moisture and its impact on commercial roofing systems.

boombox1 - default
boombox2 -
native1 -

More In Category

Mass Timber

Charlotte's new multifamily mid-rise will feature exposed mass timber

Construction recently kicked off for Oxbow, a multifamily community in Charlotteā€™s The Mill District. The $97.8 million project, consisting of 389 rental units and 14,300 sf of commercial space, sits on 4.3 acres that formerly housed four commercial buildings. The street-level retail is designed for boutiques, coffee shops, and other neighborhood services.


Construction Costs

New download: BD+C's May 2024 Market Intelligence Report

Building Design+Construction's monthly Market Intelligence Report offers a snapshot of the health of the U.S. building construction industry, including the commercial, multifamily, institutional, and industrial building sectors. This report tracks the latest metrics related to construction spending, demand for design services, contractor backlogs, and material price trends.



halfpage1 -

Most Popular Content

  1. 2021 Giants 400 Report
  2. Top 150 Architecture Firms for 2019
  3. 13 projects that represent the future of affordable housing
  4. Sagrada Familia completion date pushed back due to coronavirus
  5. Top 160 Architecture Firms 2021

Ā