Army Hospital features first-ever fire resistive, blast rated curtain wall that meets DoD Antiterrorism Standards

Sponsored Content Fire-Rated Products

Army Hospital features first-ever fire resistive, blast rated curtain wall that meets DoD Antiterrorism Standards

Project:  Army Hospital in the West Coast
Architect: RLF/US Army Corps of Engineers
Glazing Contractor: Sashco
Products:  GPX Blast fire resistive blast curtain wall system up to 2 hours (exterior); SuperLite II-XL 60 and 120 in GPX Architectural series wall framing (interior) 


By SAFTI FIRST | December 13, 2017

The 2 hour, fire resistive GPX Blast System spanned 45 feet and canted out a few degrees.

The Department of Defense (DoD) published the Unified Facilities Criteria (UFC) 4-010-01 Antiterrorism Standards for Buildings as a mandatory guideline to mitigate the threats of terrorism against buildings and ensure the safety of the individuals that inhabit them.  It applies to all newly constructed DoD Components, DoD inhabited buildings, billeting and high-occupancy housing, as well as already inhabited buildings where the renovation costs are 50% or more than the value of the building (for a complete list, please see UFC 4-010-01 section 1.8). 

One of the areas that the UFC standard addresses in great detail is blast hazard mitigation, particularly in window systems, due to the fact that the majority of the damage and injuries are caused by high velocity glass fragments on people in the building or in the vicinity when a blast occurs.  SAFTI FIRST became very familiar with the DoD’s blast requirements when they were selected by the architects to supply a fire resistive, blast rated curtain wall for an Army Hospital in the West Coast. 

The fire resistive, blast rated curtain wall in this medical facility is located near a drive-up/drop off area, which typically is exempt from building hardening requirements (see Section B-1.3).  However, since this Army Hospital is classified as a critical facility – defined in Section 1-7.3 as “buildings that must remain operational during periods of national crisis and may be subjected to a terrorist attack may warrant design to higher levels of protection that those provided in these standards” – the following blast ratings were required by the army:

  • Provide laminated glass with a minimum interlayer thickness of 0.030 in. (0.75 mm) with a load resistance determined by ASTM E1300 greater or equal to the 3-second duration equivalent design load determined from ASTM F2248.
  • In accordance with ASTM F2248, ensure that the framing members restrict deflections to 1/160 of the length of the supported edge at allowable stress levels under the equivalent 3-second design loading of 50 lbs. psf.
  • The connection design will be determined in accordance with ASTM F2248 based on two times the equivalent 3-second design loading of 50 lbs. psf.

Sections of the blast rated curtain wall also had to meet a 2-hour, ASTM E-119 fire resistive rating per Section 1023.7 of the IBC, which says:

“… Where nonrated walls or unprotected openings enclose the exterior of stairways or ramps and the walls or openings are exposed by other parts of the building at an angle of less than 180 degrees (3.14 rad), the building exterior walls within 10 feet (3048 mm) horizontally of a nonrated wall or unprotected opening shall have a fire resistance rating of not less than 1 hour.”   

In addition to the blast and fire resistive performance, the curtain wall system also had to meet windload requirements, static and dynamic water testing, air infiltration testing as well as thermal movement requirements. The design of the fire resistive, blast rated curtain wall system was also a challenge.  The design called for a glass and framing system that spanned 45 feet and canted out a few degrees. 

With all these performance and design requirements, it was clear that the architects and the US Army were looking for fire rated systems manufacturer with unique fabrication capabilities that could deliver a high-performance, custom-engineered curtain wall system.  After reviewing several proposals, the design team chose SAFTI FIRST to deliver the solution they desired.

SAFTI FIRST supplied the GPX Blast System, a complete fire resistive, blast rated, aluminum curtain wall manufactured and fabricated in Merced, CA.  The GPX Blast system uses custom ASTM E-119 rated, fire resistive SuperLite II-XL glazing with one tempered and laminated lite with a minimum interlayer of 0.030 in. designed in accordance with ASTM F2248: Standard Practice for Specifying an Equivalent 3-Second Duration Design Loading for Blast Resistant Glazing Fabricated with Laminated Glass.  It also meets a 3-second design loading of 50 lbs. psf per UFC 4-010-01 and ASTM E1300: Standard Practice for Determining Load Resistance of Glass in Buildings.

The GPX Blast System can be engineered to meet all levels of blast protection depending on the project, with static and dynamic analysis using Wingard software, which is standard industry practice and allowable under DoD standards.  It is also offered in standard and custom finishes including high performance fluoropolymer finishes by PPG, clear anodized, bronze anodized, black anodized, Decoral, any species of wood veneer, ornamental metal, and more.

SAFTI FIRST also supplied SuperLite II-XL 60 and 120 in GPX Architectural Series framing for the stairwells and atriums, which incorporated warm gray spandrel glass for a decorative effect.

1 hour fire resistive atrium walls with SuperLite II-XL 60 in GPX Architectural Series framing. Some units incorporated warm gray spandrel glass for a decorative effect.

 

2 hour fire resistive stairwells with SuperLite II-XL 120 in GPX Architectural Series framing.

 

Because this was a high-security project, SAFTI FIRST’s project management team worked with the construction team to ensure that all the schedules were met and that appropriate security clearances were obtained to ensure smooth and timely delivery of all product being supplied. 

The result is an elegant, high-performance solution that met both the aesthetic, security and performance requirements of a modern Army Hospital that promotes healing for the brave men and women who serve our country.  

Related Stories

Sponsored | Fire-Rated Products | Aug 25, 2016

FAQ on fire rated glazing applications

Choosing the correct and code approved fire rated glazing product can be confusing, this FAQ can help.

Fire-Rated Products | Jul 21, 2016

D-Blaze® Fire Retardant Treated Wood (FRTW) Earns GREENGUARD Gold Certification

Fire Retardant Wood Treatment is first of its kind to earn GREENGUARD Gold Certification

Sponsored | | Jun 30, 2016

Don’t Get Caught in the 60-minute Trap

Sponsored | | Jun 27, 2016

Fire-Rated Curtain Wall System Provides Stylish Fire Protection from the Outside In

Creating a sleek and aesthetically pleasing space, while also providing protection against the spread of fire between neighboring buildings, were key points in the development of LMN Architect’s 929 Office Tower in Bellevue, Washington.

Sponsored | Fire-Rated Products | May 6, 2016

On New York City’s bulletin on lot line requirements – and how it applies everywhere else

Determining when fire rated requirements apply, the type of fire rated glazing allowed, how much fire rated glazing can be used, and what happens when sprinklers are installed are just some of the issues that designers have to wrestle with.

Sponsored | Fire-Rated Products | Mar 7, 2016

Fire Resistive Curtain Wall Helps Hospital Meet Fire and Seismic Requirements

SaftiFirst’s custom curtain wall complied with all the seismic requirements while still blending in seamlessly with building’s design

Sponsored | | Nov 24, 2015

Fire rated doors: standards, testing and glazing requirements

There are several safe and economical alternatives to traditional wired glass for 20-45 minute vision lites

Sponsored | Fire-Rated Products | Oct 22, 2015

Made in the USA - America's Still the Place

We’ve found that sourcing products as local as possible maximizes the potential benefits to the American economy, which in turn benefits us.

Sponsored | Fire and Life Safety | Oct 13, 2015

Fire rated glass brings whimsical and reliable protection at children’s hospital

Highlights of the addition included 50 private patient rooms, family sleep and dining as well as playrooms, and a family resource center.

boombox1 - default
boombox2 -
native1 -

More In Category




halfpage1 -

Most Popular Content

  1. 2021 Giants 400 Report
  2. Top 150 Architecture Firms for 2019
  3. 13 projects that represent the future of affordable housing
  4. Sagrada Familia completion date pushed back due to coronavirus
  5. Top 160 Architecture Firms 2021