Micro data centers keep IT departments connected to computing

Data Centers

Micro data centers keep IT departments connected to computing

Over the past two years, SmithGroup has been getting more requests from clients for micro data centers.


By John Caulfield, Senior Editor | September 26, 2016

Photo courtesy SmithGroupJJR

As more companies move their data processing and computing to the cloud or co-location centers, some still want to maintain IT centers that are main distribution facilities (MDFs), “points of presence for their IT departments,” says Robert Sty, SmithGroup JJR’s Mission Critical Studio Leader.

Over the past two years, SmithGroup has been getting more requests from clients for micro data centers that provide that presence. One such facility is a 2,500-sf data center inside a two-story, 60,000-sf commercial office building in the Phoenix area, whose construction was completed last May.

Sty requested that the names of the client, the general contractor, and the designer of the building be withheld. But he did confess that this data center was “kind of an afterthought,” as it was being planned while the building was under construction. 

The micro data center holds 32 server cabinets, supporting mechanical and electrical equipment (N+1 configuration), a shipping/receiving area, and an IT lab for build/burn-in testing for servers.

“It was like putting 10 pounds in a five-pound bag,” he says. To make this work, SmithGroup JJR raised the cabinet density to 7kW per unit. “But that created a heat load,” says Sty, which would be problematic if the cooling system went down. 

The solution was to install a battery-powered flywheel backup uninterruptible power supply (UPS) onto the computer room air conditioner so the fans would keep circulating air during a power failure.

SmithGroup also deployed hot-aisle containment, a method of cooling that uses a physical barrier to guide hot exhaust airflow from server racks back to the AC return. It cools the front and back of the aisles, and mwwaintains an average room temperature of 70-75ºF.

Sty says that any client whose IT group asks for a micro data center that never goes down needs to appreciate that offices and other nonresidential spaces don’t always have the necessary infrastructure, such as a second utility feed or centralized cooling plant. Floors under data centers need to be able to handle at least 150 pounds per sf, compared to the 50-100 psf that offices are built to support. (The Phoenix office was designed to carry the heavier load.)

Data centers, regardless of size, take up more space than most clients realize. “We had to get real tight” with the mechanical and electrical equipment to keep it off of the data center floor, says Sty. 

So far, the client’s feedback has been positive. Phoenix had an unusually hot summer, with outdoor temperatures rising as high as 117ºF. But the data center “has been holding the temperature to where it’s easy enough to work around,” says Sty. And the clearances proved to be satisfactory, even with larger cabinets.

Related Stories

Giants 400 | Aug 28, 2019

Top 45 Data Center Construction Firms for 2019

Whiting-Turner, Turner, Holder, DPR, and Fortis top the rankings of the nation's largest data center sector contractors and construction management firms, as reported in Building Design+Construction's 2019 Giants 300 Report.

Giants 400 | Aug 28, 2019

Top 50 Data Center Engineering Firms for 2019

Vanderweil, ESD, kW Mission Critical, Jacobs, and EXP head the rankings of the nation's largest data center sector engineering and engineering architecture (EA) firms, as reported in Building Design+Construction's 2019 Giants 300 Report.

Giants 400 | Aug 28, 2019

Top 35 Data Center Architecture Firms for 2019

Corgan, HDR, Gensler, AECOM, and Page top the rankings of the nation's largest data center sector architecture and architecture engineering (AE) firms, as reported in Building Design+Construction's 2019 Giants 300 Report.

Data Centers | Aug 9, 2019

This will be Central Florida’s largest data center

Baker Barrios Architects is designing the project.

Data Centers | Jul 25, 2018

Data centers keep cool while staying hot-hot-hot

Cooling mission critical facilities efficiently is critical to their operations and profitability.

Data Centers | Jun 22, 2018

Can this new data center concept combat climate change?

The concept has been dubbed The Spark.

Data Centers | Feb 22, 2018

Demand for ‘hyperscale’ data centers continues to grow; U.S. leads the way

The number of so-called “hyperscale” data centers worldwide surpassed 390 at the end of 2017, with 69 more facilities in the works, according to Synergy Research Group.

Giants 400 | Oct 16, 2017

Data center market forecast: Clearly cloudy

Look for mission-critical construction to double in the next few years.

Data Centers | Oct 13, 2017

Top 35 data center construction firms

Turner Construction Co., Holder Construction, and DPR Constrcution top BD+C’s ranking of the nation’s largest data center sector contractors and construction management firms, as reported in the 2017 Giants 300 Report.

Giants 400 | Oct 12, 2017

Top 30 data center engineering firms

Syska Hennessy Group, AECOM, and Morrison Hershfield top BD+C’s ranking of the nation’s largest data center sector engineering and EA firms, as reported in the 2017 Giants 300 Report.

boombox1 - default
boombox2 -
native1 -

More In Category

Data Centers

What’s next for data center design in 2024

Nuclear power, direct-to-chip liquid cooling, and data centers as learning destinations are among the emerging design trends in the data center sector, according to Scott Hays, Sector Leader, Sustainable Design, with HED. 




halfpage1 -

Most Popular Content

  1. 2021 Giants 400 Report
  2. Top 150 Architecture Firms for 2019
  3. 13 projects that represent the future of affordable housing
  4. Sagrada Familia completion date pushed back due to coronavirus
  5. Top 160 Architecture Firms 2021