Fire resistive curtain wall brings maximum light, views and safety to Aspen Art Museum

Sponsored Content Fire-Rated Products

Fire resistive curtain wall brings maximum light, views and safety to Aspen Art Museum

The fire resistive curtain wall was supplied with custom tie-backs without exposed fasteners to make sure that it worked seamlessly with the adjacent non-rated curtain wall


By SaftiFirst | April 14, 2015
Fire resistive curtain wall brings maximum light, views and safety to Aspen Art Museum

With sections of the glass curtain wall also functioning as an elevator enclosure, it had to meet the fire resistive wall criteria ASTM E-119 for 2 hours.  

When the new Aspen Art Museum opened its doors to the public in August 2014, it was met with much excitement, and for good measure. Designed by Pritzker prize winning architect Shigeru Ban, the brand new 33,000 square foot museum boasts of large, exterior glass walls designed to keep the visitors engaged with views of the beautiful Aspen landscape. A woven screen encloses the glass curtain wall to provide shading from direct sunlight. But with the glass still exposed to the elements, it needed to be able to perform in extreme climates in addition to providing maximum daylight and clear views – and the fire resistive curtain wall was no exception. 

With sections of the glass curtain wall also functioning as an elevator enclosure, it had to meet the fire resistive wall criteria ASTM E-119 for 2 hours. In addition, the system also had to be air and water tight and meet rigorous thermal performance requirements. 

SAFTI FIRST’s engineering team provided design assistance to the architects and supplied a 2-hour fire resistive curtain wall with SuperLite II-XL 120 with Starphire Ultra-Clear Glass insulated with Viracon VE13-85 in GPX Curtain Wall Framing. SAFTI FIRST’s GPX Curtain Wall system is tested to the following standards:

  • ASTM E 283-04, Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors
  • ASTM E 331-00, Standard Test Method for Metal Curtain Walls and Doors by Uniform Static Air Pressure Difference
  • AAMA 501.1-05, Standard Test Method for Metal Curtain Walls and Doors by Uniform Dynamic Pressure
  • ASTM E 330-2, Structural Performance of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference
  • AAMA 501.4-09, Recommended Static Test Method for Evaluating Curtain Wall and Storefront Systems Subjects to Seismic and Wind Induced Interstory Drifts
  • Thermal Cycling and Condensation Evaluation
  • Interstory Vertical Displacement Tests

SAFTI FIRST also provided thermal analysis to ensure that the energy requirements for this project were met.  In an article that appeared in Glass Magazine, Jason Nimmo, Harmon Inc.’s project manager for Aspen Art Museum, said that “the exterior fire-rated IGUs were the most impressive, at 2-1/2-inch overall thickness. These IGs had to accomplish three different elements: match non-rated glass in adjacent systems, achieve the specified fire rating, and thermally insulate as well as the non-rated IGs.”

Lastly, the 2-hour fire resistive curtain wall was supplied with custom tie-backs without exposed fasteners to make sure that it worked seamlessly with the adjacent non-rated curtain wall. 

Since SAFTI FIRST provided design assistant early in the project, the engineering team was able to address the expectations and challenges of the project, as well as coordinate delivery schedules with the building team. The result is a beautiful and code compliant fire resistive curtain wall that enhanced the new Aspen Art Museum’s overall design and performance.  

--

Project Name:  Aspen Art Museum in Aspen, CO
Architects: Shigeru Ban Architects / CCY Architects
General Contractor: Turner Construction
Glazing Contractor: Harmon Inc.
Fire Rated System:  SuperLite II-XL 120 with Starphire Ultra-Clear Glass insulated with Viracon VE13-85 in GPX Curtain Wall Framing

Related Stories

| Jan 10, 2014

What the states should do to prevent more school shootings

To tell the truth, I didn’t want to write about the terrible events of December 14, 2012, when 20 children and six adults were gunned down at Sandy Hook Elementary School in Newtown, Conn. I figured other media would provide ample coverage, and anything we did would look cheap or inappropriate. But two things turned me around.

| Jan 10, 2014

Special Report: K-12 school security in the wake of Sandy Hook

BD+C's exclusive five-part report on K-12 school security offers proven design advice, technology recommendations, and thoughtful commentary on how Building Teams can help school districts prevent, or at least mitigate, a Sandy Hook on their turf.

| Jan 9, 2014

16 recommendations on security technology to take to your K-12 clients

From facial recognition cameras to IP-based door hardware, here are key technology-related considerations you should discuss with your school district clients.

| Dec 13, 2013

Safe and sound: 10 solutions for fire and life safety

From a dual fire-CO detector to an aspiration-sensing fire alarm, BD+C editors present a roundup of new fire and life safety products and technologies. 

| Dec 5, 2013

Exclusive BD+C survey shows reaction to Sandy Hook tragedy

More than 60% of AEC professionals surveyed by BD+C said their firms experienced heightened interest in security measures from school districts they worked with. 

| Nov 14, 2013

Tyco acquires Westfire Inc.

US Operations of Global Acquisition Strengthen Tyco SimplexGrinnell’s Special Hazards Fire Protection Capabilities for Mining, Telecommunications and Energy Markets

| Oct 27, 2013

SimplexGrinnell Awarded Contract by National Joint Powers Alliance for Streamlined Procurement of Fire and Life-Safety Solutions

Agreement Provides 50,000 Public Entities with Simplified Access to Comprehensive Suite of Products and Services

| Aug 23, 2013

The Exploratorium’s tall order

The newly-opened Exploratorium has brought energy and excitement to the city’s bustling waterfront.  EHDD transformed the historic Pier 15, built in 1915, to a 330,000 square foot indoor and outdoor campus, being touted as the largest net-zero building in the city and potentially the largest net-zero museum in the world.

| Aug 22, 2013

New CO-PLATE makes revenue generation through CO detector replacement easier

With the first round of system-connected carbon monoxide (CO) detectors reaching their end of life, there’s a big opportunity for dealers and installers to increase their revenue streams through CO detector replacements. System Sensor has launched a new CO-PLATE Carbon Monoxide Detector Plate to coincide with this opportunity. 

| Jul 12, 2013

Statue of Liberty Monument bolstered by Vetrotech Saint-Gobain’s fire-rated glass

The Statue of Liberty National Monument reopened to the public featuring two new fire stairwells and an elevator that will allow visitors with reduced mobility to look into the Statue’s interior structure. 

boombox1 - default
boombox2 -
native1 -

More In Category




halfpage1 -

Most Popular Content

  1. 2021 Giants 400 Report
  2. Top 150 Architecture Firms for 2019
  3. 13 projects that represent the future of affordable housing
  4. Sagrada Familia completion date pushed back due to coronavirus
  5. Top 160 Architecture Firms 2021