When the new Aspen Art Museum opened its doors to the public in August 2014, it was met with much excitement, and for good measure. Designed by Pritzker prize winning architect Shigeru Ban, the brand new 33,000 square foot museum boasts of large, exterior glass walls designed to keep the visitors engaged with views of the beautiful Aspen landscape. A woven screen encloses the glass curtain wall to provide shading from direct sunlight. But with the glass still exposed to the elements, it needed to be able to perform in extreme climates in addition to providing maximum daylight and clear views – and the fire resistive curtain wall was no exception.
With sections of the glass curtain wall also functioning as an elevator enclosure, it had to meet the fire resistive wall criteria ASTM E-119 for 2 hours. In addition, the system also had to be air and water tight and meet rigorous thermal performance requirements.
SAFTI FIRST’s engineering team provided design assistance to the architects and supplied a 2-hour fire resistive curtain wall with SuperLite II-XL 120 with Starphire Ultra-Clear Glass insulated with Viracon VE13-85 in GPX Curtain Wall Framing. SAFTI FIRST’s GPX Curtain Wall system is tested to the following standards:
- ASTM E 283-04, Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors
- ASTM E 331-00, Standard Test Method for Metal Curtain Walls and Doors by Uniform Static Air Pressure Difference
- AAMA 501.1-05, Standard Test Method for Metal Curtain Walls and Doors by Uniform Dynamic Pressure
- ASTM E 330-2, Structural Performance of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference
- AAMA 501.4-09, Recommended Static Test Method for Evaluating Curtain Wall and Storefront Systems Subjects to Seismic and Wind Induced Interstory Drifts
- Thermal Cycling and Condensation Evaluation
- Interstory Vertical Displacement Tests
SAFTI FIRST also provided thermal analysis to ensure that the energy requirements for this project were met. In an article that appeared in Glass Magazine, Jason Nimmo, Harmon Inc.’s project manager for Aspen Art Museum, said that “the exterior fire-rated IGUs were the most impressive, at 2-1/2-inch overall thickness. These IGs had to accomplish three different elements: match non-rated glass in adjacent systems, achieve the specified fire rating, and thermally insulate as well as the non-rated IGs.”
Lastly, the 2-hour fire resistive curtain wall was supplied with custom tie-backs without exposed fasteners to make sure that it worked seamlessly with the adjacent non-rated curtain wall.
Since SAFTI FIRST provided design assistant early in the project, the engineering team was able to address the expectations and challenges of the project, as well as coordinate delivery schedules with the building team. The result is a beautiful and code compliant fire resistive curtain wall that enhanced the new Aspen Art Museum’s overall design and performance.
--
Project Name: Aspen Art Museum in Aspen, CO
Architects: Shigeru Ban Architects / CCY Architects
General Contractor: Turner Construction
Glazing Contractor: Harmon Inc.
Fire Rated System: SuperLite II-XL 120 with Starphire Ultra-Clear Glass insulated with Viracon VE13-85 in GPX Curtain Wall Framing
Related Stories
| May 24, 2012
2012 Reconstruction Awards Entry Form
Download a PDF of the Entry Form at the bottom of this page.
| Apr 3, 2012
Product Solutions
Two new PV systems; a lighter shelf; and fire alarm/emergency communication system.
| Feb 6, 2012
Siemens gifts Worcester Polytechnic Institute $100,000 for fire protection lab renovation
Siemens support is earmarked for the school’s Fire Protection Engineering Lab, a facility that has been forwarding engineering and other advanced degrees, graduating fire protection engineers since 1979.
| Feb 2, 2012
Fire rated glazing helps historic university preserve its past
When the University embarked on its first major addition since the opening of Hutchins Hall in 1933, preserving the Collegiate Gothic-style architecture was of utmost importance.
| Jan 26, 2012
Siemens launches smoke detection knowledge center
New knowledge center web site demonstrates efficacy of smoke detection.
| Dec 29, 2011
Decision not to fireproof the new World Trade Center Transportation Hub criticized
Some criticized the decision, reasoning that the structure could be a terrorist target.
| Oct 19, 2011
System for installing grease duct enclosures achieves UL listing
Updated installation results in 33% space savings.
| Sep 12, 2011
Morgan Thermal Ceramics’ system for installing grease duct enclosures achieves UL listing
Updated installation results in 33% space savings.
| May 4, 2011
SAFTI FIRST to debut free apps for iPhone, iPod Touch, and iPad at AIA Convention
SAFTI FIRST, manufacturer of fire rated glass and framing solutions, will debut its mySAFTI app, the first interactive design tool that takes the guesswork out of choosing the correct fire rated glass product, at the AIA National Convention in New Orleans, May 12-14. Visit booth1634.
| Feb 10, 2011
7 Things to Know About Impact Glazing and Fire-rated Glass
Back-to-basics answers to seven common questions about impact glazing and fire-rated glass.