Schaumburg, Ill. -- Coursework is now available through the AAMA FenestrationMasters™ professional certification program, which was launched last year by the American Architectural Manufacturers Association (AAMA). This nationwide program is targeted to professionals in the window, door, skylight, curtain wall, storefront and sloped glazing industries. The FenestrationMasters program offers training content based on consensus-based AAMA standards.
The coursework can be used for the purpose of training new hires, as an introduction to the fenestration industry or to provide further education, instruction and training to current employees. The broad scope of the coursework provides an introduction to the industry, as well as an education in a range of topics affecting the commercial and residential building products market segments.
Rich Walker, AAMA's president and CEO, states, “Additional education and certification is an effective way to ensure that employees are well-trained and knowledgeable, which puts companies in a strong position to compete for business by offering customers the benefit of a well-trained staff with a broad knowledge base.”
The program coursework covers a wide range of subjects, including performance standards, product and material types and code requirements. Coursework is accessed through MyWindowClass.com, which is owned and operated by the National Glass Association. The online education format allows professionals to complete the coursework at their own pace and convenience, simply through access to any computer with an Internet connection. There are two different credentials available through the program:
* Certified FenestrationMaster: To qualify for advanced certification, a four-year degree in engineering, architecture or applied sciences in addition to four years of full-time fenestration-related experience or six years of full-time experience is required. This credential requires completion of six levels of coursework and a certification exam.
* Certified FenestrationAssociate: To qualify for entry-level certification, a four-year degree and 1 year of full-time fenestration-related experience is required or three years of full-time fenestration-related experience. This credential requires completion of four levels of coursework and a certification exam.
Descriptions for currently available courses within levels 1 and 2 are outlined below.
Level 1
* Specifying Windows and Doors: Part I: History & Features
The evolution of window and door standards and code references and introduces AAMA/WDMA/CSA 101/I.S.2/A440-08, NAFS - North American Fenestration Standard/Specification for windows, doors, and skylights (the jointly published industry standard that is applicable for use in testing and rating fenestration products)
* Specifying Windows and Doors: Part II: Basic Performance Requirements
Basic performance requirements outlined in AAMA/WDMA/CSA 101/I.S.2/A440-08, NAFS - North American Fenestration Standard/Specification for windows, doors, and skylights and performance considerations, including structural loading, water penetration and air infiltration
* Specifying Windows and Doors: Part III: Window Testing
Testing requirements for windows, including minimum test sizes and other special and optional test requirements
* Specifying Windows and Doors: Part IV: Requirements for Materials and Exterior Side-Hinged Doors
The framing materials requirements dictated by AAMA/WDMA/CSA 101/I.S.2/A440-08, NAFS - North American Fenestration Standard/Specification for windows, doors, and skylights, as well as performance requirements for exterior side-hinged doors
* Specifying Windows and Doors: Part V: Verifying Performance through Certification
The importance of product certification and the role that certification plays in verifying quality and performance
* Glass Functionality, Performance, and Types
The uses and functionality of glass in commercial buildings, as well as manufacturing and fabrication processes for different types of glass and the applications for these products
* Fabricated Glass Solutions
Various kinds of fabricated glass solutions to enhance basic glass performance, including insulating units, safety glass and fire-rated glass, as well as methods of measuring and evaluating glass performance in order to make informed glass choices
* Installation Design Considerations
This course was developed as part of the InstallationMasters™ curriculum, and covers design considerations for both windows and doors.
* Types of Windows
This course was developed as part of the InstallationMasters curriculum, and covers all types of windows.
* Types of Exterior Glass Doors
This course was developed as part of the InstallationMasters curriculum, and covers hinged glass doors, dual action hinged glass doors and sliding glass doors.
Level 2
* Air and Water Leakage Resistance Testing: Part I
Comparison of AAMA/WDMA/CSA 101/I.S.2/A440-08, NAFS - North American Fenestration Standard/Specification for windows, doors, and skylights to the field testing documents (AAMA 502, 503 and 511) to define the appropriate water test pressure, test durations and water application necessary for a successful forensic water test
* Air and Water Leakage Resistance Testing: Part II
Evaluation of case studies, as well as procedural information on recreating the leak during a forensic water test
For more information regarding the FenestrationMasters program visit www.aamanet.org/FenestrationMasters. More information about AAMA and its activities can be found at www.aamanet.org.
Related Stories
High-rise Construction | Jul 9, 2013
5 innovations in high-rise building design
KONE's carbon-fiber hoisting technology and the Broad Group's prefab construction process are among the breakthroughs named 2013 Innovation Award winners by the Council on Tall Buildings and Urban Habitat.
| May 17, 2013
5 things AEC pros need to know about low-e glass
Low-emissivity glasses are critical to making today’s buildings brighter, more energy-efficient, and more sustainable. Here are five tips to help AEC professionals understand the differences among low-e glasses and their impact on building performance.
| May 8, 2013
Preventable curtain wall failures - AIA/CES course
In many cases, curtain wall failures are caused by fairly simple errors that occur during the fabrication and installation process. This presentation will highlight common errors and when they typically occur.
| May 8, 2013
Guardian’s Scott Thomsen headlines Glass Performance Days Finland Conference, June 11-15
Scott Thomsen, president of Guardian Industries Global Flat Glass Group, will engage the global glass technorati in an opening speech at Glass Performance Days Finland June 11-15 in Tampere. In addition, Guardian technologists and scientists will present a wide variety of technical papers and glass industry innovations.
| May 6, 2013
SAFTI FIRST announces 3D Autodesk Revit models for fire rated wall, window, and door systems
SAFTI FIRST, leading USA-manufacturer of fire rated glass and faming systems, is proud to announce that Autodesk Revit models are now available for its fire rated walls, window and door systems via www.safti.com and Autodesk Seek.
| Apr 30, 2013
Tips for designing with fire rated glass - AIA/CES course
Kate Steel of Steel Consulting Services offers tips and advice for choosing the correct code-compliant glazing product for every fire-rated application. This BD+C University class is worth 1.0 AIA LU/HSW.
| Apr 8, 2013
Oldcastle Architectural acquires Expocrete Concrete Products
Oldcastle® Architectural has acquired Expocrete Concrete Products Ltd., giving North America’s largest producer of concrete masonry and hardscape products an increased presence in the high-growth region of western Canada.
| Apr 5, 2013
Projected cost for Apple's Campus 2 balloons to $5 billion
Campus 2, Apple Inc.'s proposed ring-shaped office facility in Cupertino, Calif., could cost $5 billion to build, according to a report by Bloomberg.
| Mar 23, 2013
Fire resistive curtain wall helps mixed-use residential building meet property line requirements
The majority of fire rated glazing applications occur inside the building in order to allow occupants to exit the building safely or provide an area of refuge during a fire. But what happens when the threat of fire comes from the outside? This was the case for The Kensington, a mixed-use residential building in Boston.
| Mar 20, 2013
Folding glass walls revitalize student center
Single-glazed storefronts in the student center at California’s West Valley College were replaced with aluminum-framed, thermally broken windows from NanaWall in a bronze finish that emulates the look of the original building.