The University of Chicago Hospital Group reached out to Bill Zientarski of Hi-Performance Glazing Solutions and SAFTI FIRST’s architectural representative in Illinois for a solution that combined vision, privacy and fire protection in one glazed unit.


By SaftiFirst | November 3, 2016

The new 10-story “Center for Care and Discovery” building in the University of Chicago Medical Center’s campus is dubbed as the “hospital of the future” for its high-tech design and groundbreaking scientific work. At 1.2 million square feet, it is one of the largest buildings at the campus and has already transformed the skyline of Chicago’s south side.

Albert Kahn Associates designed the new inpatient spaces on the 3rd and 4th (medical/surgical) floors which included: single-occupancy patient rooms, intensive care and observation beds, nurse’s stations, visitor and family waiting areas and general support spaces. 

Several of these rooms required a nurse’s station situated outside of the room to monitor patients during their recover from surgery. There are times when privacy is required or desired as well, so the architects specified SwitchLite Privacy Glass for these rooms. In the past, curtains or external window blinds would have been used, but were not chosen because they were determined to be more maintenance prone and tend to accumulate and trap dust and other allergens. Glass with integrated blinds are also available, but the architects wanted the ease of control and the high-tech look of electronic privacy glass that goes from completely clear to complete privacy at a flick of a switch. 

Most of the patient rooms in the medical/surgical floor required the windows to have a 45-minute fire protective rating. The University of Chicago Hospital Group reached out to Bill Zientarski of Hi-Performance Glazing Solutions and SAFTI FIRST’s architectural representative in Illinois for a solution that combined vision, privacy and fire protection in one glazed unit.

To keep a uniform look between the fire rated and non-fire rated units, SAFTI FIRST combined the SwitchLite Privacy Glass with the SuperLite II-XL 45 product, which is a clear, fire protective glazing product that reduces sound, stops smoke/flames, limits dangerous radiant heat, meets hose stream and is CPSC Cat. II impact safety rated. SAFTI FIRST sent a sample of the SuperLite II-XL 45 with SwitchLite Privacy Glass to the architects and they found it to be just what they were looking for and it satisfied all code requirements. The fire rated electronic privacy glass units were manufactured in SAFTI FIRST’s facility in Merced, California and delivered to Glass Solutions Inc., who installed the units. 

 

 

While filmed wired glass, filmed ceramics or laminated ceramics could be used in this 45 minute application, only SuperLite II-XL 45 can deliver the optical clarity they requested – wired glass has embedded wires and ceramic glass (even the premium, polished versions) have an amber tint. In addition, SuperLite II-XL 45 provides sound and radiant heat protection that neither wire nor ceramics provided. Since SuperLite II-XL 45 uses tempered glass, it is not as prone to breakage and replacement, which would be costly. For side-by-side comparisons of 45-minute fire protective products available today, click here

SAFTI FIRST was proud to offer a solution that met the fire rated code requirements and the functional vision and privacy components of the application with sound attenuation. Using switchable glass instead of curtains or integrated blinds for privacy while coupling that with clear vision complemented the architect’s high-tech design for this new and unique hospital. 

Related Stories

Sponsored | | Mar 13, 2018

An Inside Look at SAFTI FIRST

Sponsored | | Feb 13, 2018

Fire-Resistive Aluminum Frames from TGP

Sponsored | Fire-Rated Products | Feb 5, 2018

Fire rated glass opens new doors for adaptive reuse project

Project:  The Barrett Apartments in Columbus, OHArchitect: Sandvick ArchitectsGlazier: Advanced Glass SystemsProducts:  SuperLite II-XL 60 in GPX Architectural Series Framing (walls); SuperLite II-XL 60 in GPX Builders Series Temperature Rise Doors (doors) 

Sponsored | Fire-Rated Products | Dec 13, 2017

Army Hospital features first-ever fire resistive, blast rated curtain wall that meets DoD Antiterrorism Standards

Project:  Army Hospital in the West CoastArchitect: RLF/US Army Corps of EngineersGlazing Contractor: SashcoProducts:  GPX Blast fire resistive blast curtain wall system up to 2 hours (exterior); SuperLite II-XL 60 and 120 in GPX Architectural series wall framing (interior) 

Sponsored | Fire-Rated Products | Oct 25, 2017

UL-Listed does not mean code-approved

To avoid confusion, we are proposing separate charts for fire protective and fire resistive products.

Sponsored | Fire-Rated Products | Sep 14, 2017

Thermafiber® SAFB™ Formaldehyde-Free, the first of its kind in North America

Thermafiber® SAFB™ mineral wool batts are non-combustible, moisture-resistant, non-corrosive, non-deteriorating, mildew-resistant and vermin-resistant and can be installed in both steel and wood framed construction.

Fire-Rated Products | Aug 15, 2017

Walking on glass: Clear floor system offers largest two-hour fire- resistive panels

The system uses the largest tested and listed individual glass panels for two-hour fire-resistive glass floor applications.

boombox1 - default
boombox2 -
native1 -

More In Category




halfpage1 -

Most Popular Content

  1. 2021 Giants 400 Report
  2. Top 150 Architecture Firms for 2019
  3. 13 projects that represent the future of affordable housing
  4. Sagrada Familia completion date pushed back due to coronavirus
  5. Top 160 Architecture Firms 2021