Fire rated switchable glass provides privacy and fire protection at the University of Chicago Medical Center

Sponsored Content Fire-Rated Products

Fire rated switchable glass provides privacy and fire protection at the University of Chicago Medical Center

The University of Chicago Hospital Group reached out to Bill Zientarski of Hi-Performance Glazing Solutions and SAFTI FIRST’s architectural representative in Illinois for a solution that combined vision, privacy and fire protection in one glazed unit.


By SaftiFirst | November 3, 2016

The new 10-story “Center for Care and Discovery” building in the University of Chicago Medical Center’s campus is dubbed as the “hospital of the future” for its high-tech design and groundbreaking scientific work. At 1.2 million square feet, it is one of the largest buildings at the campus and has already transformed the skyline of Chicago’s south side.

Albert Kahn Associates designed the new inpatient spaces on the 3rd and 4th (medical/surgical) floors which included: single-occupancy patient rooms, intensive care and observation beds, nurse’s stations, visitor and family waiting areas and general support spaces. 

Several of these rooms required a nurse’s station situated outside of the room to monitor patients during their recover from surgery. There are times when privacy is required or desired as well, so the architects specified SwitchLite Privacy Glass for these rooms. In the past, curtains or external window blinds would have been used, but were not chosen because they were determined to be more maintenance prone and tend to accumulate and trap dust and other allergens. Glass with integrated blinds are also available, but the architects wanted the ease of control and the high-tech look of electronic privacy glass that goes from completely clear to complete privacy at a flick of a switch. 

Most of the patient rooms in the medical/surgical floor required the windows to have a 45-minute fire protective rating. The University of Chicago Hospital Group reached out to Bill Zientarski of Hi-Performance Glazing Solutions and SAFTI FIRST’s architectural representative in Illinois for a solution that combined vision, privacy and fire protection in one glazed unit.

To keep a uniform look between the fire rated and non-fire rated units, SAFTI FIRST combined the SwitchLite Privacy Glass with the SuperLite II-XL 45 product, which is a clear, fire protective glazing product that reduces sound, stops smoke/flames, limits dangerous radiant heat, meets hose stream and is CPSC Cat. II impact safety rated. SAFTI FIRST sent a sample of the SuperLite II-XL 45 with SwitchLite Privacy Glass to the architects and they found it to be just what they were looking for and it satisfied all code requirements. The fire rated electronic privacy glass units were manufactured in SAFTI FIRST’s facility in Merced, California and delivered to Glass Solutions Inc., who installed the units. 

 

 

While filmed wired glass, filmed ceramics or laminated ceramics could be used in this 45 minute application, only SuperLite II-XL 45 can deliver the optical clarity they requested – wired glass has embedded wires and ceramic glass (even the premium, polished versions) have an amber tint. In addition, SuperLite II-XL 45 provides sound and radiant heat protection that neither wire nor ceramics provided. Since SuperLite II-XL 45 uses tempered glass, it is not as prone to breakage and replacement, which would be costly. For side-by-side comparisons of 45-minute fire protective products available today, click here

SAFTI FIRST was proud to offer a solution that met the fire rated code requirements and the functional vision and privacy components of the application with sound attenuation. Using switchable glass instead of curtains or integrated blinds for privacy while coupling that with clear vision complemented the architect’s high-tech design for this new and unique hospital. 

Related Stories

| May 24, 2012

2012 Reconstruction Awards Entry Form

Download a PDF of the Entry Form at the bottom of this page.

| Apr 3, 2012

Product Solutions

Two new PV systems; a lighter shelf; and fire alarm/emergency communication system.

| Feb 6, 2012

Siemens gifts Worcester Polytechnic Institute $100,000 for fire protection lab renovation

Siemens support is earmarked for the school’s Fire Protection Engineering Lab, a facility that has been forwarding engineering and other advanced degrees, graduating fire protection engineers since 1979.

| Feb 2, 2012

Fire rated glazing helps historic university preserve its past

When the University embarked on its first major addition since the opening of Hutchins Hall in 1933, preserving the Collegiate Gothic-style architecture was of utmost importance.

| Jan 26, 2012

Siemens launches smoke detection knowledge center

New knowledge center web site demonstrates efficacy of smoke detection. 

| Dec 29, 2011

Decision not to fireproof the new World Trade Center Transportation Hub criticized

Some criticized the decision, reasoning that the structure could be a terrorist target.

| Oct 19, 2011

System for installing grease duct enclosures achieves UL listing

  Updated installation results in 33% space savings.

| Sep 12, 2011

Morgan Thermal Ceramics’ system for installing grease duct enclosures achieves UL listing

Updated installation results in 33% space savings.

| May 4, 2011

SAFTI FIRST to debut free apps for iPhone, iPod Touch, and iPad at AIA Convention

SAFTI FIRST, manufacturer of fire rated glass and framing solutions, will debut its mySAFTI app, the first interactive design tool that takes the guesswork out of choosing the correct fire rated glass product, at the AIA National Convention in New Orleans, May 12-14. Visit booth1634.

| Feb 10, 2011

7 Things to Know About Impact Glazing and Fire-rated Glass

Back-to-basics answers to seven common questions about impact glazing and fire-rated glass.

boombox1 - default
boombox2 -
native1 -

More In Category




halfpage1 -

Most Popular Content

  1. 2021 Giants 400 Report
  2. Top 150 Architecture Firms for 2019
  3. 13 projects that represent the future of affordable housing
  4. Sagrada Familia completion date pushed back due to coronavirus
  5. Top 160 Architecture Firms 2021