flexiblefullpage -
billboard - default
interstitial1 - interstitial
catfish1 - bottom
Currently Reading

Fire rated glass opens new doors for adaptive reuse project

Sponsored Content Fire-Rated Products

Fire rated glass opens new doors for adaptive reuse project

Project:  The Barrett Apartments in Columbus, OH
Architect: Sandvick Architects
Glazier: Advanced Glass Systems
Products:  SuperLite II-XL 60 in GPX Architectural Series Framing (walls); SuperLite II-XL 60 in GPX Builders Series Temperature Rise Doors (doors) 


By SAFTI FIRST | February 5, 2018
Luxury apartments with lofts

The gymnasium on the third floor was converted to luxury apartments with lofts. The gymnasium floor was preserved and became part of the apartments (photo from CASTO).

Adaptive reuse, or the process of taking an old building or structure and repurposing it for something other than what it was originally designed for, has gained a lot traction with developers and architects alike – and for many good reasons.  For one thing, it is more economical and sustainable to work with an existing structure than to demolish an old building, clean up the site, and rebuild with entirely new materials.  It also helps preserve historical structures that add character to the community, as well as reduce urban sprawl.  For the multifamily sector, we’ve seen adaptive reuse applied to old schools, government buildings, warehouses, etc. because these structures are usually centrally located in many downtown areas.  In an era where millennials and baby boomers alike are choosing to “live, work and play” in urban settings, a good amount will pay a premium to live in a building that is close to everything and boasts of history and character.

This was the case for The Barrett Apartments in Columbus, OH.  The developers chose a centrally located, abandoned historic landmark that was built in 1898 as South High School, and later on renamed as The Barrett School in honor of the school’s first principal.  Part of the allure of these reimagined luxury apartments was the fact that it was once a school – so the architects preserved not just the historic structure, but the wood floors of the basketball court, 20 ft. hallways, chalkboards, and more.  Contemporary design elements such as glazing that brings in abundant natural light were added as well, and the designers made sure that these additions complimented the building’s original Greek and Roman Design.  

 

Chalkboards from classroomsThe chalkboards from the classrooms were preserved and became part of the living units. (photo from CASTO).

 

Some of the key areas where the architects wanted to incorporate glazing were in the 1-hour exit enclosures.  In order to meet the code requirements, the architects specified fire resistive glazing tested to ASTM E-119/UL 263. 

 

Pattern-cut SuperLite II-XL 60Pattern-cut SuperLite II-XL 60 and stretch-formed custom GPX Architectural Series Framing for the 1-hour fire resistive wall and SuperLite II-XL 60 in GPX Builders Series Temperature Rise for the full-lite doors.  

 

The fire resistive glass and framing used in the 1-hour exit enclosures had to fit the arched tops, which were an integral part of the building’s design.  SAFTI FIRST supplied pattern-cut SuperLite II-XL 60 for the sidelites and transoms.  The custom GPX Architectural Series Framing were stretch-formed using SAFTI FIRST’s own machinery to ensure the frames matched the pattern cut of the glass.  SuperLite II-XL 60 was also used in the door vision panels in order to exceed 100 sq. inches.   Surface-applied muntins were added in the field to compliment the look of the windows and other non-rated storefronts in the building.  

 

SuperLite II-XL 60 in GPX Architectural Series FramingSuperLite II-XL 60 in GPX Architectural Series Framing for the walls and SuperLite II-XL 60 GPX Builders Series Temperature Rise for the full-lite doors.  

 

For the other 1-hour exit enclosures in the building that did not have arched tops, SuperLite II-XL 60 in GPX Architectural Series framing were used in the transoms and sidelites to create a 1-hour fire resistive assembly.  Again, SuperLite II-XL 60 was also used in the door vision panels in order to exceed 100 sq. inches in the door vision panel. 

It’s important to note that in the IBC, 1-hour exit enclosure applications do not allow ceramics to be used in sidelites and transoms because it does not meet the ASTM E-119/UL 263 fire resistive wall requirement.  If ceramics were to be used in the door vision panels, it would be limited to 100 sq. inches because it cannot limit the passage of radiant heat.  In order exceed the door vision panel size limitations, fire resistive glazing tested to ASTM E-119/UL 263 must be used.

The result is a beautiful, classic-yet-updated, code compliant luxury apartment complex where residents are treated to the unique charm and history of their building while enjoying the light, transparency and maximum fire protection from advanced fire resistive glazing. 

Related Stories

Sponsored | Fire-Rated Products | Jun 13, 2017

Fire resistive glass floors make a dramatic statement in Nashville’s historic neighborhood

SAFTI FIRST supplied a single glass unit comprised of non-slip rated Starphire tempered laminated Glass with 1/8” Non-Skid White Dots from Oldcastle insulated to custom SuperLite II-XL fire resistive glazing.

Sponsored | Fire-Rated Products | Jun 13, 2017

Hidden risks and costs of using sprinklers as an alternate to 1-2 hour fire resistive glazing

The ASTM E-119 test is the most stringent and most difficult test to pass for all fire rated glazing assemblies.

| Jun 5, 2017

Fire-rated frames deliver the natural look of wood

The TimberLine Series pairs a high-strength steel subframe with a wood-veneered metal cover cap to produce a slender fire-rated frame.

Sponsored | Fire-Rated Products | Mar 22, 2017

Fire resistive glazing systems provide architects, owners and envelope consultants assurance of documented performance

It may look like a regular window, but these advanced fire resistive glazing systems are recognized in the code as transparent walls because of its ability to block smoke, flames and significantly limit the passage of dangerous radiant heat.

Sponsored | | Nov 10, 2016

Fire-rated glazing replaces drywall partition to transform ‘almost unusable’ space into a ‘showstopper’

The space, which the firm hoped to use as a gathering place for employees and clients, had no access to daylight. 

Sponsored | Fire-Rated Products | Nov 10, 2016

Truly transparent: Fire resistive butt-glazed walls up to 2 hours

SuperLite II-XLM is a fire resistive multi-laminate glass product that meets ASTM E-119/UL 263/NFPA 251 and CAN/ULC S101 up to 2 hours.

Sponsored | Fire-Rated Products | Nov 3, 2016

Fire rated switchable glass provides privacy and fire protection at the University of Chicago Medical Center

The University of Chicago Hospital Group reached out to Bill Zientarski of Hi-Performance Glazing Solutions and SAFTI FIRST’s architectural representative in Illinois for a solution that combined vision, privacy and fire protection in one glazed unit.

Sponsored | Roofing and Fire Safety | Sep 21, 2016

Metal roofing provides exceptional fire resistance

Buildings with great fire resistance will likely have lower insurance costs and be restricted by fewer codes, owing to the decreased risk. 

boombox1 - default
boombox2 -
native1 -

More In Category




halfpage1 -

Most Popular Content

  1. 2021 Giants 400 Report
  2. Top 150 Architecture Firms for 2019
  3. 13 projects that represent the future of affordable housing
  4. Sagrada Familia completion date pushed back due to coronavirus
  5. Top 160 Architecture Firms 2021