Six lessons learned from our first Fitwel Viral Response Module certification

Office Buildings

Six lessons learned from our first Fitwel Viral Response Module certification


By Amanda Cunningham | Paladino | February 8, 2021

There’s what you know you know, what you know you don’t know, and what you don’t know you don’t know. Our team was as prepared and confident going into our first Fitwel Viral Response Module certification as a team can be – we’ve got more than 2000 green building projects under our belts, and significant experience working with clients at the portfolio level. We know WELL and Fitwel intimately. We have systems to break down new certification frameworks into their basic components – Which is why we felt confident going into the effort to pursue Fitwel Viral Response Module certification with an early-adopting client.

But don’t get me wrong – there was a lot to learn through the process. We didn’t know everything when we started, and I doubt that we know everything now – but we knew a lot, and now we know a lot more.

The Fitwel Viral Response Module is one of several frameworks that real estate owners and operators can use to obtain third-party certification for their efforts ensuring their properties are ready for a safer and healthier return to work. Here are six of the lessons that we learned managing the Fitwel Viral Response Module certification process.

Lesson 1: Sick leave may be a stumbling block, and we need to encourage sick people to stay home.

Paid sick leave is one of the required strategies and the certification requires the entity pursuing certification to provide employees with at least one hour of sick leave per 40 hours worked. This adds up to around 50 hours of paid sick leave per year for most full-time employees. The certification also requires that employees be allowed to use sick leave prior to it being earned for that year. It’s important to incentivize sick employees to stay home, and this requirement may demand early conversations with multiple business and human resources leaders to get buy-in.

Lesson 2: Permanently installed continuously monitoring devices are required to get full credit for Indoor Air Quality Testing because air quality is so important to fight airborne virus transmission.

Using a third-party to conduct air testing at least once per year earns 6.52 points and permanent continuous monitoring earns all available points for this strategy, which is 7.42 points.

Lesson 3: The Legionella Water Management Plan can be confusing when setting policies for entities and assets.

The certification requires a Legionella Water Management plan because legionella favors stagnant water. As most employees work from home, the water at the office has more potential for contamination by legionella unless the building management implements preventative measures. _

Despite being a requirement at the entity-level, the Legionella Water Management Plan requirement is worded in such a way that it seems to ask for asset-specific information including a flow diagram. The best practice is to keep entity policies high-level and the asset policies more detailed.

In this case, our client’s policy described the entity’s process to require individual building managers to create a flow diagram. This kept the policy broader at the entity-level and was approved by The Center for Active Design.

Lesson 4: Document informal policies

Many of our clients already do much of what is required to achieve Fitwel Viral Response certification, such as installing hand sanitizer stations, and posting signage promoting healthy practices. But many of our clients don’t also memorialize those activities as policies, so the activities can be inconsistently executed across portfolios. The requirement to formalize these policies has been valuable because the process brings clarity and consistency to a portfolio.

Lesson 5: Older buildings may need a strategy to overcome the Indoor Air Quality requirement to use MERV 13 filters.

Buildings with older equipment may be unable to accommodate MERV 13 filters. Alternative (and potentially expensive) compliance is available through UV light or mobile filtration. If it’s cost-prohibitive to meet the Indoor Air Quality requirements, the entity certification can be applied to only those assets that are suitable for the Fitwel Viral Response certification in the short-erm. Additional assets can be added to the Fitwel Viral Response entity portfolio as mechanical systems are upgraded. You may also want to review the WELL Health Safety Rating as an alternative, as it does not include prerequisites – you can learn about the WELL Health Safety Rating Indoor Air Quality requirements here.

Lesson 6: The scope of each strategy will not be the same.

Some strategies apply to employees under the control of building management (which can be fuzzy when an entity seeking certification works with a third-party manager), while others include all building occupants. Some require implementation in spaces within the control of building management, and others require implementation throughout the building. Be careful to be clear on the scope of the strategy before you develop the policy, and not after!

These are six lessons that we learned, to be added to our collective knowledge and experience. And through this process, our curiosity has been ignited about what comes next for these rating systems and frameworks – as we all learn about what works (and what doesn’t) together, the feedback will inform future releases of the rating systems, and decisions among real estate owners and operators.

If you work in commercial real estate, there is no doubt that COVID is high on your radar, and the decisions about how to open, stay open, and operate safely and continuously (and profitably) are top-of-mind. It’s COVID today, and who-knows-what tomorrow. Viral response and planning will be part of the new normal for the foreseeable future.

More from Author

Paladino | Jan 10, 2022

The future of regenerative building is performance-based

Why measuring performance results is so critical, but also easier said than done.

Paladino | May 26, 2021

Injecting embodied carbon capability into the integrated design and construction process

Embodied carbon is defined as the carbon footprint of a material, and is expressed in metric tons of CO2e.

Paladino | May 12, 2021

Climate modeling for a resilient business and future

This post explores changes that developers and their teams need to make to their risk and resilience strategies by climate modeling for climate change.

Paladino | Apr 26, 2021

Building performance requirements are coming: Are you ready?

Building Performance Requirements are trending nationwide and are likely coming to a county near you.

Paladino | Jan 14, 2021

Shift your energy to carbon

Now is the right and necessary time for the commercial real estate industry to shift its environmental strategy from just energy, a carbon contributor, to carbon itself.

Paladino | Nov 13, 2020

5 tips when designing for daylight

Daylight modeling is a tool to examine how daylight interacts with a building, and how that natural light behaves within interior spaces.

Paladino | Jul 16, 2020

COVID readiness: IWBI and USGBC seek to help businesses quantify risk

In an effort to address the risks of COVID-19 at the building scale, USGBC and IWBI have analyzed existing certification guidelines and drafted new, relevant content.

Paladino | Jun 29, 2020

The glass box paradox

Glass box designs have an energy performance problem.

Paladino | Jun 5, 2020

3 strategies to improve the wellness of building systems and gain tenant trust

Three operational issues that must be prioritized for every building in order to achieve tenant trust are air quality/ventilation, relative humidity, and building commissioning.

Paladino | Apr 1, 2020

Green cleaning and the coronavirus

If your cleaning teams use bleach to disinfect buildings from Coronavirus, will you put your LEED certification at risk?

boombox1 - default
boombox2 -
native1 -

More In Category

AEC Innovators

3 ways the most innovative companies work differently

Gensler’s pre-pandemic workplace research reinforced that great workplace design drives creativity and innovation. Using six performance indicators, we're able to view workers’ perceptions of the quality of innovation, creativity, and leadership in an employee’s organization.


Laboratories

HGA unveils plans to transform an abandoned rock quarry into a new research and innovation campus

In the coastal town of Manchester-by-the-Sea, Mass., an abandoned rock quarry will be transformed into a new research and innovation campus designed by HGA. The campus will reuse and upcycle the granite left onsite. The project for Cell Signaling Technology (CST), a life sciences technology company, will turn an environmentally depleted site into a net-zero laboratory campus, with building electrification and onsite renewables.



halfpage1 -

Most Popular Content

  1. 2021 Giants 400 Report
  2. Top 150 Architecture Firms for 2019
  3. 13 projects that represent the future of affordable housing
  4. Sagrada Familia completion date pushed back due to coronavirus
  5. Top 160 Architecture Firms 2021