ASHRAE issues correction on changes to addendum r to ANSI/ASHRAE Standard 62.1-2007 on ventilation for IAQ

Earlier today, ASHRAE distributed a news release, ASHRAE Proposes Mechanical Ventilation Requirements for Naturally Ventilated Buildings. This release contained erroneous information about proposed changes in addendum r to ANSI/ASHRAE Standard 62.1-2007, Ventilation for Acceptable Indoor Air Quality. Requirements regarding mechanical ventilation for naturally ventilated buildings are actually included in addendum n, which has completed public review and will be included in the 2010 version of Standard 62.1, which is expected to be available in spring 2010. 

The proposed changes open for review in addendum r focus on the IAQ procedure, which is a performance-based approach to compliance with the standard, and allows for designers to adjust the ventilation requirements for a building or space based on performance factors which are unique to the building.  These performance factors might include the use of low-emitting materials in the space or the known presence of a contaminant source.  The first public review draft of Addendum r removed a method of complying with the IAQ procedure by designing the ventilation system in the same way as an existing successful building.  Based on public review comments, this approach was put back into the standard, but with new restrictions.  These include a requirement that a mass-balance analysis of the building's air quality be performed in every case.  This will require that the designer identify contaminants of concern for every building or space where the IAQ procedure is used, along with associated concentration or exposure limits.

ORIGINAL PRESS RELEASE FOLLOWS:

Working to help ensure the quality of indoor air of naturally ventilated high-rise residential buildings, ASHRAE is proposing that mechanical systems be required for such building types.

Proposed addendum r would require that most buildings with natural ventilation have mechanical ventilation systems installed that are capable of meeting the requirements of the standard’s Ventilation Rate Procedure.  The mechanical system is to be used when windows are closed due to extreme outdoor temperatures, noise, security concerns, etc. 

The proposed addendum is open for public review from Sept. 11 until Oct. 26, 2009. ANSI/ASHRAE Standard 62.1-2007, Ventilation for Acceptable Indoor Air Quality, sets minimum ventilation rates and other requirements for commercial and institutional buildings. 

“Most buildings using natural ventilation in the United States are high-rise residential buildings that often have no form of outdoor air intake other than operable windows,” Roger Hedrick, Standard 62.1 committee chair, said. “This results in buildings with inadequate ventilation, because the occupants then leave the windows closed in order to run the air conditioning, keep out noise, etc. The committee felt it needed to strengthen the existing prescriptive requirements for natural ventilation to improve their corresponding IAQ benefits.”

Also open for public review during the same time period is proposed addendum g, which would add information on using demand controlled ventilation systems. Coverage of DCV systems in the standard is not yet comprehensive, but this addendum provides needed clarifications on the issue.  

To view a copy of the addenda open for public review, go to www.ashrae.org/publicreviews. Copies of public review drafts are only available during public review periods.
      














         
 

Comments on: "ASHRAE issues correction on changes to addendum r to ANSI/ASHRAE Standard 62.1-2007 on ventilation for IAQ "

The colorful ribboned flooring at Toronto’s Corus Quay mimics the iconic corkscr
The colorful ribboned flooring at Toronto’s Corus Quay mimics the iconic corkscr
Discussions of commercial flooring tend to focus on the floor covering or finish material. This is hardly surprising, since the covering is the part of the floor that stakeholders see, interact with, and care about most. The...
The use of light load-bearing glass to create transparent stairs, floors, and ot
The use of light load-bearing glass to create transparent stairs, floors, and ot
Glass has taken on new life in recent building years. Long valued for its transparency and lightness, glass is now also being considered for its structural and protective capabilities. Beyond the technique known as...
Building owners must plan ahead for roof replacement to avoid emergency leak rem
Building owners must plan ahead for roof replacement to avoid emergency leak rem
No building owner wants to be caught unprepared by catastrophic roof failure. Emergency roof replacements tend to be more expensive than planned ones, and damage to interiors may mean unrecovered costs and detrimental...
AIA: New Developments in Concrete Construction
AIA: New Developments in Concrete Construction
Concrete has long been a reliable building material for commercial and institutional projects. Yet recent trends, including the growth in hospitality and urban rental project starts, as well as mixed-use towers and transit-...
AIA Rainscreens BD+C DEcember 2011
AIA Rainscreens BD+C DEcember 2011
Until recently, it has been lighting, mechanical, and control system upgrades which have received the most attention in the green building movement. At long last, the industry is now recognizing building enclosures as a long...
Brick and stone masonry have served as reliable and valuable elements of commercial building projects for centuries, gracing urban and rural landscapes since time immemorial. Building Teams have trusted clay brick to bring...
Making the Most of the Reconstruction Boom Reconstruction in its many forms—tenant improvements, retail fitouts, adaptive reuse, historic preservation, gut rehab, and so on—is keeping many design and construction firms...
The topic of water shortages is nothing new, as cities around the globe struggle with drought, water quality, supply constraints, and failing infrastructures. However, the idea of new plumbing codes and design standards...
Guard booths, stations and shelters are defense strategy linchpins, becoming increasingly integral to perimeter defense planning. Before evaluating the efficacy of different guard booth configurations, and before selecting a...
From the company that brought you Construction Computing Magazine’s 2011 BIM Product of the Year ArchiCAD 15, the “Get There Faster with ArchiCAD” whitepaper examines five critical areas to explore before making your final...
Download Complete White Paper Download Introduction Download Chapters 1-4Defining Net-Zero Energy Buildings
Our seventh White Paper on Green Buildings focuses on the role of water in sustainable design and construction. The editors conclude with a set of 21 detailed recommendations for the consideration of the Building Teams, home...