FREE
Subscriptions:
Quick Links:
:: Print Edition
:: Digital Edition
:: eNewsletters
:: Reader Service
:: Webcasts
:: White Papers
:: Award Programs
:: Store

Site Search
Powered by Zibb

Sponsored By
Supplier Search
Products/Services
Companies

Site Sponsors

Directories
Office Furniture
Computer Desks
Canopies
Awnings
Cabanas
Easi-Set Industries
Fabric Structures
Tension Structures Furniture Store
Honeywell
Nora® Rubber Flooring
Office Chairs
Alcan
Flooring
NFBA
HP Workstations



NIST WTC recommendations finally adopted in the model building codes





More than two years after the National Institute of Standards and Technology released its 30 recommendations for improving the safety of tall buildings based on its post-9/11 investigation of the World Trade Center towers, the prescriptive recommendations are finally making their way into the model building codes.

In June, the International Code Council released a supplement to its International Building Code that incorporates a number of changes and additions based, in part, on the NIST WTC investigation recommendations. The changes include:

  • An additional exit stairway for buildings more than 420 feet in height.
  • A minimum of one fire service access elevator for buildings more than 120 feet in height.
  • Increased bond strength for fireproofing (nearly three times greater than what is currently required for buildings 75-420 feet in height and seven times greater for buildings more than 420 feet in height).
  • Field installation requirements for fireproofing to ensure that: installation complies with the manufacturer's instructions; the substrates (surfaces being fireproofed) are clean and free of any condition that prevents adhesion; testing is conducted to demonstrate that required adhesion is maintained for primed, painted or encapsulated steel surfaces; and the finished condition of the installed fireproofing, upon complete drying or curing, does not exhibit cracks, voids, spalls, delamination, or any exposure of the substrate.
  • Special field inspections of fireproofing to ensure that its installed thickness, density, and bond strength meet specified requirements, and that a bonding agent is applied when the bond strength is less than required due to the effect of a primed, painted, or encapsulated steel surface. The inspections are to be performed after the rough installation of mechanical, electrical, plumbing, sprinkler, and ceiling systems.
  • Increasing by one hour the fire-resistance rating of structural components and assemblies in buildings 420 feet and higher.
  • Explicit adoption of the “structural frame” approach to fire resistance ratings that requires all members of the primary structural frame to have the higher fire resistance rating commonly required for columns. The primary structural frame includes the columns; other structural members having direct connections to the columns, including girders, beams, and trusses; and spandrels and bracing members designed to carry gravity loads.
  • Luminous markings delineating the exit path (including vertical exit enclosures and passageways) in buildings more than 75 feet in height to facilitate rapid egress and full building evacuation.

NIST's lead WTC investigator Shyam Sunder said a broad industry coalition is planning to submit two more model code changes to be considered for the next edition of IBC in 2009.

The first recommends that structures be designed to mitigate disproportionate progressive collapse and ensure, for the first time, minimum structural integrity and robustness requirements for structures as complete systems.

The second code change would require the use of a nationally accepted standard for conducting wind tunnel tests routinely used for determining wind loads in the design of tall buildings.

For more, visit www.nist.gov.


  

© 2008, Reed Business Information, a division of Reed Elsevier Inc. All Rights Reserved.




E-mail a friend Printer-friendly version



Talk Back

There are no comments posted for this article.

POST A COMMENT ON THIS ARTICLE




Advertorials

Staron Surfaces by Samsung
Unique surface offerings in Solid Surfaces, Quartz and its expanded Tempest line.

Marvin Windows and Doors
Substantial proportions, sturdy hinges, and different hardware options make the Marvin Commercial door a great choice for non-residential applications.
The Venting Picture Window from Marvin combines the beauty of a picture window with the opportunity for cross ventilation.

Dayton Superior
Concrete Accessories, Chemical Systems, Forming and Shoring, Masonry Accessories and Paving Systems.

Johns Manville Insulation
Turn Architecture Concepts into Physical 3D Models 5x-10x Faster. In-house.
Request Complimentary 3D Printing for Architecture Starter Kit

San Diego Gas & Electric Company
Take advantage of available incentives up to $2,000 per unit on green, energy-saving measures for qualifying new construction initiatives.